AJDRAJNR - American Journal of Neuroradiology

This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Beckett, W. W.
Right arrow Articles by Hoffman, J. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Beckett, W. W., Jr
Right arrow Articles by Hoffman, J. C., Jr

American Journal of Neuroradiology, Vol 11, Issue 5 1049-1053, Copyright © 1990 by American Society of Neuroradiology


ARTICLES

Duplex Doppler sonography of the carotid artery: false-positive results in an artery contralateral to an artery with marked stenosis

WW Beckett Jr, PC Davis and JC Hoffman Jr
Department of Radiology, Emory University School of Medicine, Atlanta, GA 30322.

Anecdotal reports have described a false-positive "jet effect" or velocity increase in the carotid artery contralateral to an artery with significant stenosis or occlusion when using duplex Doppler sonography. In this study, the frequency, significance, and possible reasons for this finding were evaluated by a retrospective comparison of duplex sonography and angiography. Twenty-three patients with unilateral 81- 100% carotid artery stenosis who underwent both duplex sonography (16 Acuson, seven Quantum) and angiography were evaluated. In 14 patients, there was an accurate or slight underestimate (less than 20%) of stenosis present in the internal carotid artery contralateral to an artery with tight stenosis/occlusion. In nine, a velocity increase in the internal carotid artery resulted in overestimation (10-80%) of the actual degree of stenosis. In one of these nine patients, real-time images were sufficient to explain the velocity increase on the basis of vessel tortuosity. In one, falsely elevated velocity resulted from inaccurate assignment of the Doppler angle of incidence in a patient in whom real-time visualization of a distal internal carotid lesion was poor. In four of the nine patients, cross filling via the circle of Willis toward the side of greater stenosis occurred. However, seven of 14 patients in whom there was duplex sonography/angiography agreement or slight duplex sonography underestimation also had cross filling. Vertebral artery patency did not correlate well with the presence of a "jet effect."(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
Vasc MedHome page
M. Gerhard-Herman, J. M Gardin, M. Jaff, E. Mohler, M. Roman, and T. Z Naqvi
Guidelines for noninvasive vascular laboratory testing: a report from the American Society of Echocardiography and the Society for Vascular Medicine and Biology
Vascular Medicine, August 1, 2006; 11(3): 183 - 200.
[PDF]


Home page
RadioGraphicsHome page
H. R. Tahmasebpour, A. R. Buckley, P. L. Cooperberg, and C. H. Fix
Sonographic Examination of the Carotid Arteries
RadioGraphics, November 1, 2005; 25(6): 1561 - 1575.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
D. Mukherjee, J. S. Yadav, V. J. Howard, G. Howard, and W. H. Baker
Effect of Contralateral Occlusion on Long-Term Efficacy of Endarterectomy in the Asymptomatic Carotid Atherosclerosis Study (ACAS) Response
Stroke, June 1, 2001; 32 (6): 1443 - 1448.
[Full Text] [PDF]


Home page
StrokeHome page
R. D. Henderson, D. A. Steinman, M. Eliasziw, and H. J. M. Barnett
Effect of Contralateral Carotid Artery Stenosis on Carotid Ultrasound Velocity Measurements
Stroke, November 1, 2000; 31(11): 2636 - 2640.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
M. M. Horrow, J. Stassi, A. Shurman, J. D. Brody, C. L. Kirby, and H. K. Rosenberg
The Limitations of Carotid Sonography: Interpretive and Technology-Related Errors
Am. J. Roentgenol., January 1, 2000; 174(1): 189 - 194.
[Abstract] [Full Text] [PDF]


Home page
VASC ENDOVASCULAR SURGHome page
S. P. Roddy, J. M. Estes, A. P. Harrington, P. A. Heggerick, T. F. O'Donnell Jr., and W. C. Mackey
Comparison of Preoperative and Postoperative Duplex Ultrasound Evaluation of the Contralateral Carotid Artery
Vascular and Endovascular Surgery, November 1, 1999; 33(6): 663 - 669.
[Abstract] [PDF]