AJDRAJNR - American Journal of Neuroradiology

This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tsuruda, J. S.
Right arrow Articles by Remley, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tsuruda, J. S.
Right arrow Articles by Remley, K.

American Journal of Neuroradiology, Vol 12, Issue 2 237-241, Copyright © 1991 by American Society of Neuroradiology


ARTICLES

Effects of magnetic susceptibility artifacts and motion in evaluating the cervical neural foramina on 3DFT gradient-echo MR imaging

JS Tsuruda and K Remley
Department of Radiology, University of California, San Francisco 94143- 0628.

The purpose of this study was to evaluate in vitro the effects of magnetic susceptibility and motion on the estimation of neural foraminal diameter with three-dimensional Fourier transformation (3DFT) gradient-recalled MR imaging as compared with CT. A cervical spine phantom was constructed from desiccated human cervical vertebral bodies embedded in a water-based proteinaceous gel. The phantom was imaged with thin-section 1.5-mm axial CT and 1.5-mm axial 3DFT gradient- recalled MR using a constant TR (35 msec) and flip angle (5 degrees), while the TE was varied from 11 to 22 msec. During imaging, the phantom either was kept stationary or underwent subtle, intermittent motion. Compared with CT, MR consistently underestimated the diameters of the neural foramina, leading to overestimation of neural foraminal stenosis. The degree of over-estimation varied directly with increasing TE values, from 8% (TE = 11 msec) to 27% (TE = 22 msec). Motion artifacts also increased foraminal overestimation and mimicked osseous hypertrophy. The effect of image degradation due to motion was noted to increase with longer TE values. Image degradation caused by magnetic susceptibility and motion artifacts can be minimized by using the shortest TE possible. We do not recommend the use of 3DFT gradient- recalled MR imaging for the evaluation of cervical radiculopathy if patient motion is anticipated.


This article has been cited by other articles:


Home page
Br. J. Radiol.Home page
D Birchall, D Connelly, L Walker, and K Hall
Evaluation of magnetic resonance myelography in the investigation of cervical spondylotic radiculopathy
Br. J. Radiol., August 1, 2003; 76(908): 525 - 531.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
V. Baskaran, F. S. Pereles, E. J. Russell, S. A. Georganos, A. Shaibani, K. A. Spero, E. A. Krupinski, A. Zhang, and J. P. Finn
Myelographic MR Imaging of the Cervical Spine with a 3D True Fast Imaging with Steady-State Precession Technique: Initial Experience
Radiology, May 1, 2003; 227(2): 585 - 592.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
E. R. Melhem, R. Itoh, and P. J. M. Folkers
Cervical Spine: Three-dimensional Fast Spin-Echo MR Imaging--Improved Recovery of Longitudinal Magnetization with Driven Equilibrium Pulse
Radiology, January 1, 2001; 218(1): 283 - 288.
[Full Text]


Home page
Am. J. Neuroradiol.Home page
R. M. Quencer
The American Journal of Neuroradiology 1980-1999 Where We Have Been: Where We Are Going
AJNR Am. J. Neuroradiol., January 1, 2000; 21(1): 1 - 8.
[Full Text]


Home page
Am. J. Neuroradiol.Home page
J. S. Ross
Newer Sequences for Spinal MR Imaging: Smorgasbord or Succotash of Acronyms?
AJNR Am. J. Neuroradiol., March 1, 1999; 20(3): 361 - 373.
[Full Text]