AJDRAJNR - American Journal of Neuroradiology

This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tsuruda, J. S.
Right arrow Articles by Saloner, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tsuruda, J. S.
Right arrow Articles by Saloner, D.

American Journal of Neuroradiology, Vol 12, Issue 3 481-488, Copyright © 1991 by American Society of Neuroradiology


ARTICLES

Dural sinus occlusion: evaluation with phase-sensitive gradient-echo MR imaging

JS Tsuruda, A Shimakawa, NJ Pelc and D Saloner
Department of Radiology, University of California, San Francisco 94143- 0628.

The purpose of this study was to evaluate the usefulness of limited- flip-angle, phase-sensitive velocity imaging with gradient-recalled- echo (VIGRE) MR when combined with spin-echo MR in the diagnosis of dural sinus thrombosis. The VIGRE sequence consists of a rapid single- slice acquisition, 50/15/2 (TR/TE/excitations), and 30 degrees flip angle. At each slice position, a total of four images were reconstructed; these consisted of one magnitude image and three images sensitive to proton motion in each orthogonal direction. The flow direction and flow velocity (cm/sec) were obtained from each of the phase images, and results were correlated with data obtained from a phantom experiment. In normal controls, dural sinus velocities ranged from a mean of 9.9 to 14.4 cm/sec for the transverse and superior sagittal sinuses, respectively. Three patients with proved dural sinus occlusion were studied with spin-echo images at 1.5 T. Three- dimensional time-of-flight MR angiography was also performed in one patient. The presence of dural sinus occlusion was determined by the lack of flow void on the spin-echo images, the absence of phase shift on the VIGRE study, and the presence of retrograde flow on the phase image in the sinus proximal to the occluded segment. Time-of-flight angiography overestimated the extent of the thrombosis caused by spin saturation. Follow-up VIGRE studies detected the formation of collateral flow in one patient and recanalization with the establishment of normal antegrade sinus flow in the other. We conclude that phase-sensitive MR imaging is helpful in establishing the diagnosis and extent of dural sinus occlusion.(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
RadioGraphicsHome page
J. L. Leach, R. B. Fortuna, B. V. Jones, and M. F. Gaskill-Shipley
Imaging of Cerebral Venous Thrombosis: Current Techniques, Spectrum of Findings, and Diagnostic Pitfalls
RadioGraphics, October 1, 2006; 26(suppl_1): S19 - S41.
[Abstract] [Full Text] [PDF]


Home page
J Am Board Fam MedHome page
M. Grover
Cerebral Venous Thrombosis as a Cause of Acute Headache
J Am Board Fam Med, July 1, 2004; 17(4): 295 - 298.
[Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
K. Kudo, S. Terae, A. Ishii, T. Omatsu, T. Asano, K. Tha, and K. Miyasaka
Physiologic Change in Flow Velocity and Direction of Dural Venous Sinuses with Respiration: MR Venography and Flow Analysis
AJNR Am. J. Neuroradiol., April 1, 2004; 25(4): 551 - 557.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
K. Kirchhof, T. Welzel, O. Jansen, and K. Sartor
More Reliable Noninvasive Visualization of the Cerebral Veins and Dural Sinuses: Comparison of Three MR Angiographic Techniques
Radiology, September 1, 2002; 224(3): 804 - 810.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
N. R. Mehta, L. Jones, M. A. Kraut, and E. R. Melhem
Physiologic Variations in Dural Venous Sinus Flow on Phase-Contrast MR Imaging
Am. J. Roentgenol., July 1, 2000; 175(1): 221 - 225.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
L. Liauw, M. A. van Buchem, A. Spilt, F. T. de Bruïne, R. van den Berg, J. Hermans, and M. N. J. M. Wasser
MR Angiography of the Intracranial Venous System
Radiology, March 1, 2000; 214(3): 678 - 682.
[Abstract] [Full Text]


Home page
RadioGraphicsHome page
F. G. Greiner and D. Takhtani
Neuroradiology Case of the Day
RadioGraphics, July 1, 1999; 19(4): 1098 - 1101.
[Full Text] [PDF]


Home page
StrokeHome page
J. M. Valdueza, K. Schmierer, S. Mehraein, and K. M. Einhaupl
Assessment of Normal Flow Velocity in Basal Cerebral Veins: A Transcranial Doppler Ultrasound Study
Stroke, July 1, 1996; 27(7): 1221 - 1225.
[Abstract] [Full Text]


Home page
StrokeHome page
J. M. Valdueza, M. Schultz, L. Harms, and K. M. Einhaupl
Venous Transcranial Doppler Ultrasound Monitoring in Acute Dural Sinus Thrombosis : Report of Two Cases
Stroke, July 1, 1995; 26(7): 1196 - 1199.
[Abstract] [Full Text]