AJDRAJNR - American Journal of Neuroradiology

This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Babbel, R.
Right arrow Articles by Hunt, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Babbel, R.
Right arrow Articles by Hunt, S.

American Journal of Neuroradiology, Vol 12, Issue 5 849-854, Copyright © 1991 by American Society of Neuroradiology


ARTICLES

Optimization of techniques in screening CT of the sinuses

R Babbel, HR Harnsberger, B Nelson, J Sonkens and S Hunt
Department of Radiology, University of Utah Medical Center, Salt Lake City 84132.

The number of screening examinations of the sinuses performed with CT has markedly increased owing to the widespread and increasing use of endoscopic sinonasal surgery. We reviewed scans from 500 patients who had screening CT examinations of the sinuses for preendoscopic evaluation of inflammatory sinonasal disease to better define an optimal imaging protocol. Three aspects of direct coronal imaging of the paranasal sinuses were investigated: (1) preparation of the patient prior to the examination; (2) technical factors of the CT study, including positioning of the patient, optimal coronal angle, slice thickness, and CT exposure factors; and (3) data display. Our experience indicates that pretreatment of the patient with maximal medical therapy enables the best preendoscopic definition of anatomy, disease pattern, and nonreversible disease component for the treating surgeon. CT technical factors are optimized with scanning in the prone position with thin (3-mm) sections obtained through the anterior paranasal sinuses. This allows optimal visualization of the ostiomeatal unit. The remaining posterior portions of the sinuses are adequately imaged with thicker slices (5 mm). The coronal scan angle used is less critical. Exposure factors (mAs) can be reduced dramatically without image compromise. Data display is optimized when the bone algorithm is used to acquire the data and with image display at intermediate window center and width level. Use of the techniques outlined in this article results in a cost-effective yet diagnostic scan of the sinuses with decreased radiation exposure to the patient.


This article has been cited by other articles:


Home page
Br. J. Radiol.Home page
S A Sohaib, P D Peppercorn, J A Horrocks, M H Keene, G S Kenyon, and R H Reznek
The effect of decreasing mAs on image quality and patient dose in sinus CT
Br. J. Radiol., February 1, 2001; 74(878): 157 - 161.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
W. Huda, E. M. Scalzetti, and G. Levin
Technique Factors and Image Quality as Functions of Patient Weight at Abdominal CT
Radiology, November 1, 2000; 217(2): 430 - 435.
[Abstract] [Full Text]