AJDRAJNR - American Journal of Neuroradiology

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ulmer, J. L.
Right arrow Articles by Moran, P. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ulmer, J. L.
Right arrow Articles by Moran, P. R.

American Journal of Neuroradiology, Vol 17, Issue 5 805-819, Copyright © 1996 by American Society of Neuroradiology


ARTICLES

Magnetization transfer or spin-lock? An investigation of off-resonance saturation pulse imaging with varying frequency offsets

JL Ulmer, VP Mathews, CA Hamilton, AD Elster and PR Moran
Department of Radiology, Bowman Gray School of Medicine, Winston-Salem, NC, USA.

PURPOSE: To characterize near-resonance saturation pulse MR imaging on a 1.5-T scanner in order to gain insight into underlying mechanisms that alter tissue contrast and to optimize the technique for neuroimaging. METHODS: Off-resonance saturation pulses were applied to T1-weighted, spin-density-weighted, and T2-weighted sequences at frequency offsets ranging from 50 Hz to 20,000 Hz down field from water resonance. Suppression ratios were determined at each offset for phantom materials (MnCl2 solution, gadopentetate dimeglumine, corn oil, water, and agar), normal brain structures, and a variety of brain lesions. RESULTS: Signal suppression of MnCl2 on T1-weighted images occurred at offsets of less than 2000 Hz even though no macromolecules were present in the solution. Only those phantom materials and tissues with short or intermediate T1 relaxation times and relatively large T1/T2 ratios were sensitive to changing frequency offsets. Suppression of brain increased from approximately 20% at 2000 Hz offset to approximately 45% when the offset was reduced to 300 Hz. In human subjects, the net effect of reducing the frequency offset was to increase T2 contrast on T1-weighted, spin-density-weighted, and T2- weighted images. Distilled water and contrast material did not suppress except at very low offsets ( < 300 Hz). A frequency offset of 300 Hz was optimal for maximizing conspicuity between most contrast-enhancing lesions and adjacent brain while preserving anatomic detail. CONCLUSION: Suppression of MnCl2 indicates that magnetization transfer is not the sole mechanism of contrast in near-resonance saturation MR imaging. Spin-lock excitation can reasonably explain the behavior of the phantom solutions and the increase in T2 contrast of tissues achieved as the frequency offset is decreased from 2000 Hz to 300 Hz. Below 300 Hz, saturation is presumably caused by spin-tip effects. With our pulse design, an offset of 300 Hz is optimal for many routine clinical imaging examinations.


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
S. Takashima, J. Wang, F. Takayama, M. Momose, T. Matsushita, S. Kawakami, A. Saito, and T. Ishiyama
Parotid Masses: Prediction of Malignancy Using Magnetization Transfer and MR Imaging Findings
Am. J. Roentgenol., June 1, 2001; 176(6): 1577 - 1584.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
V. P. Mathews, K. S. Caldemeyer, M. J. Lowe, S. L. Greenspan, D. M. Weber, and J. L. Ulmer
Brain: Gadolinium-enhanced Fast Fluid-attenuated Inversion-Recovery MR Imaging
Radiology, April 1, 1999; 211(1): 257 - 263.
[Abstract] [Full Text]