AJDRAJNR - American Journal of Neuroradiology

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Schmalbrock, P.
Right arrow Articles by Welling, D. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Schmalbrock, P.
Right arrow Articles by Welling, D. B.

ARTICLE

Assessment of Internal Auditory Canal Tumors: A Comparison of Contrast-Enhanced T1-Weighted and Steady-State T2-Weighted Gradient-Echo MR Imaging

Petra Schmalbrock,a, Donald W. Chakeresa, James W. Monroea, Ashok Saraswata, Beth A. Milesa and D. Bradley Wellinga

a From the Departments of Radiology (P.S., D.W.C., J.W.M., A.S.) and Otolaryngology (B.A.M., D.B.W.), The Ohio State University, Columbus, OH.

BACKGROUND AND PURPOSE: Although contrast-enhanced T1-weighted MR imaging is the standard of reference for diagnosing tumor in the cerebellopontine angle, high-resolution T2-weighted imaging may show more details of the seventh and eighth cranial nerve branches, resulting in more accurate tumor volume measurements. The purpose of this study was to compare two MR sequences for their ability to delineate internal auditory canal tumors.

METHODS: Twenty-seven ears in 21 patients with 16 confirmed schwannomas were studied with the 3D T2-weighted prototype segment-interleaved motion-compensated acquisition in steady state (SIMCAST) and the T1-weighted contrast-enhanced spoiled gradient-echo (SPGR) techniques. Twenty-eight axial sections were acquired using parameters of 17/3.3 (TR/TE), a 40° flip angle, a 20 x 15-cm or 22 x 16-cm field of view (FOV), a 512 x 256 matrix, and a 0.4- or 1.2-mm section thickness for the SIMCAST technique, and 30/4.2, a 30° flip angle, a 20 x 20-cm FOV, a 512 x 288 matrix, and a 1.5-mm section thickness for the SPGR technique. Tumor appearance and depiction of surrounding anatomy, including the cranial nerves, were evaluated. Tumor volumes were measured by manual tracing.

RESULTS: Both sequences clearly identified tumors that ranged in size from 0.06 to 3.0 cm3. Measurements on both sequences agreed, on average, within 14%. The information from both sequences was complementary. SIMCAST usually delineated the CSF spaces better, whereas SPGR more clearly showed the tumor/brain boundary.

CONCLUSION: SIMCAST and SPGR are suitable for tumor detection and volume measurements. SPGR has somewhat better contrast, but SIMCAST excels at depicting the surrounding anatomy and tumor involvement of the seventh and eighth cranial nerves.




This article has been cited by other articles:


Home page
Am. J. Neuroradiol.Home page
S. Naganawa, T. Koshikawa, H. Fukatsu, T. Ishigaki, and T. Fukuta
MR Cisternography of the Cerebellopontine Angle: Comparison of Three-dimensional Fast Asymmetrical Spin-echo and Three-dimensional Constructive Interference in the Steady-state Sequences
AJNR Am. J. Neuroradiol., June 1, 2001; 22(6): 1179 - 1185.
[Abstract] [Full Text] [PDF]