American Journal of Neuroradiology 20:1445-1451 (9 1999)
© 1999 American Society of Neuroradiology
ARTICLE
Recurrent Inverted Papilloma: Diagnosis with Pharmacokinetic Dynamic Gadolinium-EnhancedMR Imaging
a From the Departments of Radiology (P.H.L., C.F.Y., H.B.P., M.T.W.), Otolaryngology (S.T.C.), and Medical Education and Research and Biostatistics (L.P.G.), Veterans General Hospital-Kaohsiung, National Yang-Ming College, Taiwan, ROC; the Department of Hospital Management (W.C.H.), Chia-Nan College of Pharmacy and Science, Tainan, Taiwan, ROC; and the Institute of Computer and Information Engineering (C.C.H., C.N.L.), National Sun Yat-Sen University, Kaohsiung, Taiwan, ROC.
BACKGROUND AND PURPOSE: Dynamic gadolinium-enhanced MR imaging has been used successfully to identify post-treatment recurrence or postoperative changes in rectal and cervical carcinoma. Our purpose was to evaluate the usefulness of dynamic gadolinium-enhanced MR imaging for distinguishing recurrent inverted papilloma (IP) from postoperative changes.
METHODS: Fifteen patients with 20 pathologically proved lesions (recurrent IP, 12; fibrosis or granulation tissue, eight) were enrolled in the study. Three observers, blinded to pathologic results, independently evaluated conventional MR images, including T1-weighted (unenhanced and postcontrast), proton-densityweighted, and T2-weighted spin-echo images. Results then were determined by consensus. Dynamic images were obtained using fast spin-echo sequences at 5, 30, 60, 90, 120, 150, 180, and 300 seconds after the injection of gadolinium-diethylenetriamine penta-acetic acid. Time-signal intensity curves of suspected lesions were analyzed by a pharmacokinetic model. The calculated amplitude and tissue distribution time were used to characterize tissue, and their values were displayed as a color-coded overlay.
RESULTS: T2-weighted images yielded a sensitivity of 67%, a specificity of 75%, and an accuracy of 70% in the diagnosis of recurrent IP. Contrast-enhanced T1-weighted images yielded a sensitivity of 75%, a specificity of 50%, and an accuracy of 65%. Pharmacokinetic analysis showed that recurrent IP had faster (distribution time, 41 versus 88 seconds) and higher (amplitude, 2.4 versus 1.2 arbitrary units) enhancement than did fibrosis or granulation tissue. A cut-off of 65 seconds for distribution time and 1.6 units for amplitude yielded a sensitivity of 100% and a specificity of 100% for diagnosing recurrent IP.
CONCLUSION: Dynamic MR imaging can differentiate accurately recurrent IP from postoperative changes and seems to be a valuable diagnostic tool.
This article has been cited by other articles:
![]() |
T.Y. Jeon, H.-J. Kim, S.-K. Chung, H.-J. Dhong, H.Y. Kim, Y.J. Yim, S.T. Kim, P. Jeon, and K.H. Kim Sinonasal Inverted Papilloma: Value of Convoluted Cerebriform Pattern on MR Imaging AJNR Am. J. Neuroradiol., September 1, 2008; 29(8): 1556 - 1560. [Abstract] [Full Text] [PDF] |
||||
![]() |
A.A.K. A. Razek, A.Y. Kandeel, N. Soliman, H.M. El-shenshawy, Y. Kamel, N. Nada, and A. Denewar Role of Diffusion-Weighted Echo-Planar MR Imaging in Differentiation of Residual or Recurrent Head and Neck Tumors and Posttreatment Changes AJNR Am. J. Neuroradiol., June 1, 2007; 28(6): 1146 - 1152. [Abstract] [Full Text] [PDF] |
||||