AJDRAJNR - American Journal of Neuroradiology

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Simon, J. E.
Right arrow Articles by Frayne, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Simon, J. E.
Right arrow Articles by Frayne, R.

BRAIN

Fluid-Attenuated Inversion Recovery Preparation: Not an Improvement over Conventional Diffusion-Weighted Imaging at 3T in Acute Ischemic Stroke

Jessica E. Simona,b, Diana K. Czechowskyb, Michael D. Hillb,c,d, Ashley D. Harrisa,b,e, Alastair M. Buchana,b and Richard Fraynea,b,e

a Seaman Family MR Research Centre, University of Calgary, Foothills Medical Centre, Calgary, AB T2N 2T9 Canada
b Department of Clinical Neurosciences, University of Calgary, Foothills Medical Centre, Calgary, AB T2N 2T9 Canada
c Department of Community Health Sciences, University of Calgary, Foothills Medical Centre, Calgary, AB T2N 2T9 Canada
d Department of Medicine, University of Calgary, Foothills Medical Centre, Calgary, AB T2N 2T9 Canada
e Department of Radiology, University of Calgary, Foothills Medical Centre, Calgary, AB T2N 2T9 Canada

Address reprint requests to Jessica Simon, Department of Clinical Neurosciences, University of Calgary, Rm 1162, Foothills Medical Centre, 1403 29th ST NW, Calgary, AB T2N 2T9 Canada

BACKGROUND AND PURPOSE: Change in signal intensity due to acute ischemic stroke can be detected on diffusion-weighted (DW) images soon after symptom onset. Fluid-attenuated inversion recovery (FLAIR) DW imaging suppresses signal intensity from water and has been suggested to be better than conventional DW imaging as a diagnostic imaging technique in acute stroke. We compared the signal intensity-to-noise ratio (SNR) and contrast-to-noise-ratio (CNR) between ischemic and normal tissues by using these two sequences.

METHODS: Twenty stroke patients underwent imaging less than 6 hours after stroke onset by using both acquisition methods. The SNR of six regions of interest in normal brain and one region in ischemic brain were compared on both DW imaging and FLAIR DW imaging. We also compared CNR in normal and ischemic tissues. The calculated apparent diffusion coefficient (ADC) maps from each acquisition technique were similarly assessed.

RESULTS: The SNR was significantly lower for FLAIR DW imaging than for DW imaging (P < .05). The CNR between normal and ischemic tissue was also lower on FLAIR DW imaging (P < .05). SNR and CNR of the ADC maps were significantly different (P < .05) for all tissues except the putamen and white matter (for SNR and CNR) and globus pallidus (for CNR only).

CONCLUSION: Ischemic tissue on FLAIR DW imaging was significantly less conspicuous than on DW imaging and potentially limits the clinical utility of this sequence.




This article has been cited by other articles:


Home page
RadiologyHome page
P. E. Chen, J. E. Simon, M. D. Hill, C.-H. Sohn, P. Dickhoff, W. F. Morrish, R. J. Sevick, and R. Frayne
Acute Ischemic Stroke: Accuracy of Diffusion-weighted MR Imaging--Effects of b Value and Cerebrospinal Fluid Suppression
Radiology, January 1, 2006; 238(1): 232 - 239.
[Abstract] [Full Text] [PDF]